Series StormceptorŽ

About Series StormceptorŽ

Series Stormceptor Normal Flow
Normal flow
See How it Works

Product Description

During infrequent high flow events, peak stormwater flows will pass over the diverting weirs in the first and second chamber and continue through the by-pass chamber into the downstream sewer system. This by-pass activity creates pressure equalization across both units, preventing scouring. A portion of incoming sediment continues to be diverted by the weirs in the first and second structure into the treatment chamber.

StormceptorŽ takes the place of a traditional structure in a storm sewer system.

Uses/Applications

Designed to treat run-off from larger drainage areas, the Series StormceptorŽ can more than double the treated drainage area of the In-Line StormceptorŽ System.

Product Technical Information

Series Stormceptor High Flow
High Flow Conditions
See How it Works

Series Inline Unit

[STC 11000, 13000, 16000]

  • Two 8 ft. diameter upper by-pass structures.
  • Two 10 ft. or 12 ft. diameter treatment chambers.
  • Inlets and outlet of upstream structures must be 180 degrees.
  • Minimum direction change from inlet to outlet of downstream structure is 90 degrees.
  • Joining weir must be installed between both units.
  • Frame and covers orientated to over riser pipes and oil ports in both units.

The series models are available in 11,000, 13,000 and 16,000.

You can inspect and maintain the Series StormceptorŽ from the surface, without entry into the unit. Maintenance will be restored when the stored volume reaches 15 percent of the StormceptorŽ capacity, or immediately in the event of a spill.

Maintenance intervals vary depending on the application. We recommend quarterly inspections during the first year of installation to accurately establish the maintenance schedule.

Remove oil and sediment through each of the 24-inch diameter outlet riser pipes. Alternatively, you may remove floatables and hydrocarbons through the six inch oil inspection port. Both steps must be performed in each of the two structures

The requirements for the disposal from StormceptorŽ are similar to that of any other Best Management Practice (BMP). Consult local guidelines or contact your StormceptorŽ area marketing manager prior to disposal of the separator contents.

Additional Information

The In-Line StormceptorŽ works as a NPDES Phase I Best Management Practice and is an ideal solution for communities dealing with the NPDES Phase II Regulations.